opening a shop and will be doing

Im opening a shop and will be doing this in the next couple of weeks, This approach provides enough friction to hold them solidly. Specific choices that help promote gentle dust paths include: Minimize the flex pipe. Available in abrasion resistant. That tiny static shock you might feel is plenty to cause a cloud of dust to blow up. Simple method of small shop dust collection ductwork design: First you need to choose a material for your duct work.

Vacmaster 2 1/2" to 1 1/4" Wet/ Dry Vac Accessory Adaptor, V21A, POWERTEC 70107 4-Inch T-Fitting Dust Hose Connector, POWERTEC 70204 Dust Collection Rectangular Hood Nozzle for 2-1/2 Dust Collection Hose Fittings, POWERTEC 70234 2-1/2" Pipe Coupling, Clear, Big Horn 11456 4-Inch ABS Plastic Wall Mounted Blast Gate with One Quick Disconnect End for Dust Collection Systems, Transition Reducer, 2.5in to 3in Stainless Steel Tubing Transition Adapter Reducer Pipe Replacement, POWERTEC 70293 Cyclone Dust Collector and Separator Kit w/Clear 6 Gallon Dust Bucket, Hoses, Reducers, Couplers and Hose Clamps, Nordfab H5284-6" x 8" Industrial Dust Collection Reducer, Woodstock D4225 4-Inch to 2-1/4-Inch Eccentric Reducer, Shop Fox D4870 2-1/2" Benchtop Tool Dust Collection Kit, Woodstock W1050 Dust Collection Basics Book, Woodstock D4247 2-1/2-Inch Low Profile Dust Port, Woodstock W1141 3-Inch Aluminum Blastgate, ALPHA ECOGRDW5 Ecoguard Type W5 Dust Collection Cover 5" for Wide Kerf Cutting, 6" Swivel Ball Joint (Raw Ends) for Dust Collection and CNC Routers, 8" Swivel Ball Joint (Raw Ends) for Dust Collection and CNC Routers, Festool 492753 Boom Arm Workstation For CT 22 And CT 33 Dust Extractors, Loc-Line Vacuum Hose Component, Acetal Copolymer, Sheet Metal Duct Adapter, 3" Diameter, 10" Swivel Ball Joint (Raw Ends) for Dust Collection and CNC Routers, Tool- AA battery powered Drill Assistance dust collector with laser level tool, 4" Swivel Ball Joint (Raw Ends) for Dust Collection and CNC Routers, Your recently viewed items and featured recommendations, Select the department you want to search in. Nordfab ducting can be integrated with existing ductwork to enhance efficiency and prevent leakage or installed as a brand new system. Maybe remote. Hard, fixed ducting - Based on the application, hard fixed dust collector ducting is typically made of plastic, galvanized steel, or stainless steel material. My plan is not to use the manifold and use a main instead. Id be interested in hearing how it works. Once it is started hopefully it will slide the rest of the way in without a problem. When comparing types of material for my dust collection pipes, my local plumbing store recommended dryer vent pipe.

Our dust collector ducting is designed to withstand high air pressure, minimize air resistance and reduce static pressure loss making it ideal for material handling applications. For aluminum to work it would have to be a lot thicker, which would make it pretty expensive. As far as piping that dust collector for 6, it depends on the actual CFM capability of the system (most DCs are rated much higher than they actually deliver), and the length of your duct runs. I dont need to do all that piping and nothing is in the way! Ensure that each machine is continuously grounded to the. I am looking forward to the second installment about connecting various tools to the system as that is always a pain since tool mfgs cant seem to agree on a standard.

Combustible dusts are fine particles that present an explosion hazard when suspended in air under certain conditions according to Combustible Dust resource page with links to several presentations by Air Handling Systems as well as links to additional resources such as NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Hi Rick.

Would such a small system work, in your opinion? Shapers | I would recommend at a minimum a 1.5 HP dust collector with a 1 micron filter and a short 4 hose that you would connect to each tool. Also the store I work for stocks some 26 gauge duct work, 4 inch and 6 inch ys still have to be ordered in but if customers ordered enough of these they might become an in stock item.

Did you integrate the switches in your equipment? You answered several questions I had about setting up a dust collection system in my shop. Thank you. The unit has lots of capacity, a very high MERV rating for the filter and low noise rating (75 dbA at 10 ft.). They only cover metal ducts that are grounded. I would relocate to shorten the lengths if possible. While I liked your piece overall I know from handling PVC daily that in generates enough static you shouldnt ignore the risk. Im still flip-flopping over which piece of PVC (pipe or fitting) I want attached to the flex, based on what is going where in the shop and how much moving will happen. End Matchers | Feeders/Conveyors | Finishing Equipment | Thanks for the feedback. I have a 2Hp 1200CFM DC.

220 + 395 = 615 which would be a 5" duct. Very helpful as I plan out a system. I did figure out how to help with the couplings I remembered back thirty-#$%^#@& years ago and replacing the handlebar grips on my bicycle. Blast gates. Wish I had read a a long time ago. Madeline Do not forget to connect the, wires to each other with wire nuts when two branches, Ensure that the entire system is grounded. At the output of the collector, there will be 2 lanes. SWMBO just returned from visiting relatives for a few weeks and giving up a little shop time this week should help me to maintain tranquility. When I reached out to touch it, the spark arched about 6 and snapped quite loudly. I just installed a dust collector with a 7 OD pipe, how do I hook it up to a plastic system? Thank you. only requires a simple disconnect process. I have one bell end of pipe that I managed to get flex onto, though if I wanted it to connect more deeply I would have needed a heat gun. I looked thru your pics and text and dont see anywhere where you have 6 flex over PVC pipe, only inside PVC fittings.

I was just going to use 4 duct as that is what is pushed by all the woodworking vendors on their sites and catalogsnow you have me thinking about 6!!! Seal the joints? Either PVC or metal will work well. Even among standard promulgated by the same standards-developing organization, the definitions vary significantly.. These simple steps will drastically reduce your dust explosion risks. Tahnks for writing the article, it was very good for me.

Air Handling Systems handles fabrication and inventory. In most cases, flanged ducting is throw away. Spiral pipe is up to 20% stronger than smooth pipe systems, due to spiral reinforcement in manufacturing process. 800-867-8968, Tags: Blast Gate, Ducting, Ductwork, dust collection, Pvc, Spiral Pipe, Tool Port. Run the ducting so that it ends directly above each dust port. Items out of stock and custom-made parts generally will be shipped in 5 working days. We recommend using flexible hose, (flex-hose) to connect the woodworking machine to the, dust collector. The primary enemy of ideal dust collection is static pressure. Preventative Maintenance | Some tools provide adequate dust collection ports, while others (most) dont and you will need to devise your own enhancements. If there is emerging data in this area then I want to be informed, and I believe that there will be widespread interest across our readership as well. We will remain open for business performing essential operations during this crisis, supplying industrial, military, and healthcare operations with our products. Dovetailers | Dust Collection | Edgebanders | Run hard pipe as close to the tool as possible, and use just the flex pipe you need for convenience in case you need to move the tool. You are not pulling air through that pipe fast enough with 24 of 6 pipe. Tenoners |

This supports the use of PVC as safe. Ive had a 2HP cyclone dust collector for years, its a collection of home improvement store galvanized pipe (probably a combination of 26-30 gauge, I never really check) and high quality smooth elbows and wyes purchased from a variety of mail order sources. check out grizley they have a very good dust pipe assortment TOP SHELF !!!!!!! Could I have a link for it? Table Saws | What are your feeling? I incorated 12 v switch system to start the system automatically.

I think this will definitely be the way to go.

Can be taken apart and reconfigured quickly and easily. Oil Extraction in the Gulf of Mexico needs fresh air supplied to explosion proof testing labs. Hi Paul- On metal you will likely need to seal the joints to minimize leaking. PVC duct systems are common in hobbyist woodworking shops but users are encouraged to perform their own due diligence to verify their insurance coverage. *Quoted freight applies to the lower 48 states only. New shop in new house, so I installed a Harbor Freight DC, Oneida Dust Deputy, 4 ABS for most of system, and a blast gate at each drop. I want to make piping for my 1200 cfm dust collector. Great article. If it is still tight you can warm up the flex tube a bit with a heat gun. Step Four: On Your Drawing, Sketch Out The Position of Your Main Duct Line. Over 90% of stock orders can be shipped within 24 hours or less. Otherwise, youll definitely get some air flow, but youll probably be down in the 200 300 CFM range at the end of the run which will be marginal but better than nothing. Privacy Policy | Hi Frank, thanks for the kind words. However, plastic flex-hose and plastic duct, are an insulator, and dust particles moving against the, walls of the plastic duct create a static electrical build. I use some metal ones on my PVC ducts as well because they are more durable than the cheap plastic ones. Once again, many thanks for the informative discussion.

I do recommend a direct connection to all machines and a open connection to portable machines that are used sometimes. Ive had to do this on some dust collectors. This is the beauty of on-line articles; the ability to keep the discussion going long after the articles are published. The benefits are significant. I want to use pvc ducting and your article gives me a good start. I think you will find that woodworking retailers are slowly getting up to speed on dust collection, but they are not on the cutting edge of research in this area. The branch would be sized at 5-3-4, with 5" being the largest reducing to 4" with a 3" branch going out the side at 30 degrees. I just tucked one side in, and then reached through the other end of the coupler and pull the flex pipe into the coupler. Paul-Woodworkers Guild of America. I agree; if you plan to ground the ducting, it would be far better to do it as you install it rather than waiting until later. If you have made an investment in a powerful dust collector, that is a great first step toward creating a healthy shop environment.

The HVAC piping in most home centers is 30 gauge or thinner, so it is not a good choice for dust collection. However, if the machine can be isolated with a blast gate, you will not need to add the two air volumes. When you set up your ductwork consider installing additional ports at logical locations for possible future expansion. Therefore it is important to have your duct layout in mind when you buy your dust collector, and have your vendor suggest a model that can deliver enough suction at your tools. Beginning February 12, 2021, Nordfab will include a 25% materials surcharge on all products.

And if you were using a four inch line a low cost take off is the plastic end caps found in rolls of carpet at your builders supply. Printing and publishing facilities need ozone removal. Problem is, the wiring is all done for the DC in a certain place in the shop.

Source: Our staff is working remotely wherever possible and we will maintain a bare minimum staff on-site to perform basic operations of order processing and accounting. For the stroke sander you will probably want to build a shroud of some sort, and position it directly behind where the dust flies off on the left end as you face the machine. Be sure that you extend the bare copper wire down all, branches of the system. Equipment Reconditioning | Copyright 2022 Air Handling Systems | All Rights Reserved | Site by: Dust Collection Frequently Asked Questions. Your target is 4000 ft/min, and youll start to have serious problems at anything below 2000.

different shops, so I have never bothered with grounding mine. ductwork torit collector donaldson dust wood duct installation parts furnace installing environmental solutions service cartridge connection type authorized know need

Payment Options | Just because you may not have had any issues in the past does not mean that you are capturing the dust safely. Thanks If using plastic, blast gates to direct air flow, the grounding wire must, be jumped (see Figure 41) around the blast gate without, We also recommend wrapping the outside of all plastic, ducts with bare copper wire to ground the outside of the, system against static electrical build up. Pharmaceutical manufacturers need special flexible hose for clean rooms. Additional charges may apply. Hello. dust systems pipe hobby air handling spiral fittings In a separate article I will walk through the dust collection design at each tool in my shop to help you complete your dust collection system design. dust systems baghouse collector usaf engineers designing installing pulse challenging jet been most http://home.comcast.net/~rodec/woodworking/articles/DC_myths.html Our fabrication department is dedicated to producing quality products. If I have three separate lines, Id need a 6-4 reducer going into each of the three ports on the collector. Call us at (800) 367-3828 to discuss your next project or email your quote to sales@airhand.com. Would it be better to use 4 or 6 pvc, since 5 is not available. Here is the experts response, thank you for the question: I havent tried it, but it seems like it might be too soft and could potentially collapse. I would try to arrange your tools so that the big dust producers are closest to the DC, and pipe them using 6.

I searched the internet and read books to do the best I could and I see I managed to get some things right. I am going to use a 5hp Super Dust Gorilla so as never to be wanting more power.

Paul. This is on OSHAs hot list for a good reason. Its probably no more expensive than plastic. SWMBO first, soap eventually.

These are just a few examples of how we service pollution control. This allows you to easily make changes or expand your present system in the future. I have 6 from the DC to my table saw and drum sander which is 5 feet from my DC but the miter saw is 23 feet away. The more info about dust collection I can get the better In other words, you are better off if you have a single blast gate designated for each tool, and therefore each tool gets the full air flow from the dust collector.

I use PVC because I find it to be much cheaper in my area, and I prefer working with it over metal. We recommend inserting a, continuous bare copper ground wire (see Figure 40) inside, the entire duct system and attaching the wire to each. Blast gates are setup at each tool, and you only have it open when you are using that tool; all other gates remained closed. You must also confirm that the dust collector, is continuously grounded through the electrical circuit to, If you connect the dust collector to more than one, machine by way of a non-conducting branching duct, system and blast gates, the system must still be grounded, as mentioned above. Watch the next newsletter for specifics on how I optimized dust collection at various tools in my shop.

Paul-WWGOA. Normally you can remove that and have a single 6 (or whatever) larger port.

I have a small shop and will only be using one tool at a time, Its like having ABS in your car, you might not know how many times it saves you. They have a wide flange to allow attachment to the housing and given they are thrown away weekly its hard to beat the cost. On rush orders, we can also handle your Next Day, Second Day or 3-Day Select requests.

If 6 is the way to go why then dont the stores sell fittings for this size.go figure!

IMPORTANT SAFETY NOTE: All dust systems must be grounded to avoid a buildup of static electricity in the ductwork or filter.

On the 4 it is a bit looser, so I have used duct tape to secure it. grounded woodworking machine and dust collector. The shop/garage is 16x24. DC, with suction capacity of 3560 CFM and Static Pressure 16.8. Our products are designed to meet industrial standards. Wide Belt Sanders | The results were quite interesting when I tested before & after my Clear Vue upgrade: http://local.wordpress/articles/product-reviews/stepping-up-to-better-dust-collection/, Hi Paul; heres an update on my comment from a month ago. Top subscription boxes right to your door, 1996-2022, Amazon.com, Inc. or its affiliates.

Any guidance would be appreciated. Paul-WWGOA. Does that make sense?

I just keep going back and forth what to do off the main. If youre human, you wont plug it in to each machine every time you do a cut, and will wind up breathing dust for those just a quick cut moments. Upcoming Events | Paul-WWGOA. The big issue is whether I should go with a bigger DC to support plumbing drops for each machine or a smaller DC unit and drag a hose around to each machine. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Could you use copper pipe? This seem to make excellent sense when they explained PVC is meant to move water (a heavier substance) and dryer vent pipe is specifically designed to move air (a lighter substance). Producing round metal fittings has been our business for over sixty years. Its slippery enough, and once it dries its stickier than using nothing. at Ys and Ts should be made with wire nuts. Continue to the second machine. I know the answer is basically on the length of the main and static pressure and design. Determine the diameter of CFM requirements at machine one. Step Three: Figure out the Total CFM Required For Your Whole System.

A 10 length of 6 PVC costs about $20 at a big box store, and it probably costs $100 to ship it to someones home.

Also do not discount air restrictions after the power.

spiral pipe installation slip flanges flange joints ring angle vanstone connection single methods main However, according to the OSHA Combustible Dust ANPR (Advanced Notice of Proposed Rulemaking), No single, universally accepted definition of combustible dust is available. the spark can come from turning on or off any electric switch or motor, or the gas hot water heater in the corner of your basement shop. I encourage you to accept the fact that most tools come with insufficient tool ports. I just bought a dust collector with 4 in. If it is super tight I would cut a slit into the flex, cutting through a couple strands of the wire that wraps around it, and that should help you get it started. All those wood shavings swirling in a plastic funnel was a wicked combination. Thanks again for sharing your thoughts on this.

hose for now, but will be able to plumb in drops in the future if I move to a larger shop. Is it wise to take a 4 run off the 6 then branch off to say a planer and a table saw or should each run be separate. Thanks, Paul. For the smaller machines I use a big shop vac! I placed a blast gate at each machine along with a pushbutton start stop station. Buying local might provide savings due to the high shipping costs of large pipes. I would either go all 4, or remove the 6x4x4x4 reducer and go 6 for your main trunk. To prevent static charge and shocks I lined the PVC and fittings with a strip of aluminum foil duct tape with the ends wrapped around the pipe ends and fitting ends so that continuity is maintained from the machine all the way to the dust collector which is electrically grounded. I would encourage you to do some research on the specific machine to see if any owners are using pipe larger than 6, and see how their performance is. all I can find is 6 inch pipe. Now you want to make sure that you are doing everything you can to get the most out of it. 10% leakage on a 50,000 CFM system will lose enough air to add five to six machines. Flexible hose ducting - Flexible hoses are made of rubber or plastic material and have a metal grounding helix that must be grounded at each end to prevent static electricity buildup and dangerous sparks.

Sitemap 27

opening a shop and will be doing