laerdal suction unit battery life

The Kit reduces the Airflow and Battery run time.

It is normal that the adapter becomes warm when in use.

Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.

Vacuum Range: 80 500+ mmHg (11 67 kPa)

Cat. %PDF-1.4 %

laerdal pinit

When using the LCSU 4 at home, take care to keep it out of reach of children and pets.

Battery = 90 days), Air Flow @ Vacuum Inlet: 27 LPM (free flow) typical, Vacuum - Range: 50 - 550+ mmHg (6.7 - 73.3 kPa), 300 ml canister version: 18.5 cm x 26.2 cm x 8.12 cm (7.3" x 10.3" x 3.2"), 800 ml canister version: 23.6 cm x 19 cm x 23.6 cm (9.3" x 7.5" x 9.3"). =============================== The battery is warranted for 90 days. Manufacturers use sponsored listings to help you discover and purchase their listing right where you'll be sure to see them.

Easy to convert between the canister systems. To prolong Battery lifetime it is recommended to place the Battery on continuous charge.

rated with an efficiency of 99.97% down to a particle size of 0.3 gm.



No. lcsu laerdal

No.

WarningDo not pump any cleaning solution or other liquids through the vacuum pump, i.e.

WarningIf the Low Battery symbol illuminates, immediately switch to an external power source to avoid interrupting operation. JavaScript seems to be disabled in your browser. laerdal lsu Does the Laerdal Compact Suction Unit 4 (LCSU 4) come with tubing and a Yankauer tip? No.

See Charging Instructions (Chapter 5).

External Battery Charger Unless otherwise specified, the information in these User Guides applies to all versions. gYpV:+

This is prevented by coding of the outlet. Refer to the Laerdal Global Warranty for terms and conditions. Do not attempt to use the LCSU 4 if parts are damaged or missing.LCSU 4 800 ml (Cat.

The 300 ml Canister (Cat. A $20 service charge will be assessed on all returned checks.

Vacuum Tubing

Important InformationThis User Guide covers two main versions of LCSU 4; one configured with an 800 ml Canister, and one with a 300 ml Canister.

DisposalWhen discarding the LCSU 4, we recommend it be discarded according to local protocol. Refrigerated items are only shipped Monday Wednesday and will arrive in 1 2 days.

No.

This might damage the device, and cause electrical hazards. Big vacuum regulator dial By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. Returned merchandise must be sent freight prepaid and be received in new, resalable condition.

289 0 obj <> endobj xref

0000006837 00000 n Orders under $100.00 will be charged a $12.50 shipping and handling fee.



laerdal suction

DC Power-Cord (Cat. Plug the AC/ DC Adapter into mains power.

Do not immerse the LCSU 4 or allow it to stand in water or other liquids.

The replacement battery for theLaerdal LSU Suction Unit is a high quality battery that is designed to provide excellent performance, durability and long life in your device. Do not store the LCSU 4 next to a heater. 0000013921 00000 n It is intended for the intermittent operation to remove secretions, blood or vomit from a patients airway to allow ventilation. If you are a dealer or reseller, are using collect billing, or you live outside of the contiguous United States, you do not qualify for free shipping on orders over $175, and different shipping costs apply.

Poor vacuum connection be-tween LCSU 4 and Canister, Follow the procedure for proper assembly of the Canister and Tubing, Lid (800 ml canister only) not properly sealed, Check that the lid is properly secured to the Canister, Check that the Patient tube is not blocked or twisted, or alternately replace the tube. suction laerdal lcsu

No.

See Battery Charging (Chapter 5). Earn points on every online order.

With a suction range from 50 to 550 mmHg, the LCSU 4 can be adjusted for use in the most challenging situations, whether it be a newborn or adult - ensuring you always have just the right amount of power. High flow / High vacuum Delinquent accounts will be referred for collection.

The Canister is disposable and cannot be cleaned. may not be eligible for credit.

Follow local protocols for backup suction devices. Do not attempt to open or disassemble the pump or electrical accessories.

Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

Noice level: 46 56 dBA (80 500 mmHg), Dimensions / weight No 886115) is offered as an Optional Accessory. No-tools-necessary field changeablebattery

laerdal suction 300ml compact unit Contact local authorities to determine the proper method of disposal of the soiled canister and patient tube. All parts should be properly assembled (Canister, Tubes etc.).

Higher vacuum levels are generally selected for oropharyngeal suction, and lower vacuum levels are usually selected for tracheal suctioning and the suctioning of children and infants.

If the Battery level illuminates RED, the battery should be charged. laerdal bemis airway

The Scale illuminates Green to indicate the level of vacuum/suction strength, The Light Blue area indicates reduced suction levels for infants and small children. CautionDo not cover the Charger.

If, by chance, an item is backordered, it will be shipped to you immediately upon our receipt.

Disconnect the LCSU 4 from external power prior to cleaning.



Unauthorized service attempts, opening, or tampering with the LCSU 4 or its electrical components can damage or disable the device and will void the Limited Warranty. Refrigerated items cannot be returned.

880052/880062 are approved according to RTCA/DO-160G Section 21 Category M but limited to battery operation use only.

suction laerdal lsu paramedic veterinary emergency pump battery unit

AC And DCCords Life-Assist is one of the nation's largest distributors of emergency medical supplies When contacting us please try to provide as much information as possible. 0000040199 00000 n 0000003921 00000 n The vacuum level will display on the Suction Level Setting Scale. Call 800.558.6270 for product expiration date, Replacement Battery for Laerdal Suction Unit, Generic. Excluding the internal Battery, there are no user-serviceable/user-replaceable parts inside the LCSU 4 Main Unit. Prior to returning any purchase, please contact customer service at (800) 824-6016 or email [emailprotected] to obtain a return authorization number.

After each reassembly, and before returning an LCSU 4 to operational use, the Device Test should be performed: WarningDo not block the patient tube for more than 10 seconds at vacuum levels greater than 300 mmHg.

It is our service policy to ship orders the same day we receive them, providing the order is placed by 4:00 pm Monday through Friday. This appliance is marked according to the European directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE). 0000012392 00000 n laerdal lcsu



allied suction lsp laerdal l190 1270 list

Pay $10.50 for ground shipping on orders under $175.

Your email address will not be published. Disposal must be carried out in accordance with local environment regulations for waste disposal. Redeem for product credit. =======

LCSU 4 300 ml (Cat. Air Flow:>30 LPM

NoteIf LCSU 4 does not maintain the desired suction performance level, refer to Troubleshooting instructions (see Chapter 7).

High-Efficiency Filter Kit (for 800 ml Version).

Warranties are limited to those offered by the manufacturer.

laerdal suction compact battery unit shipping accessories Battery charging time may be increased when charging below 10 oC. laerdal suction

0000001616 00000 n

laerdal suction 300ml compact unit

For more detailed information about the treatment, recovery, and recycling of this product, please contact your local city office, your household waste disposal service or the Laerdal representative where you purchased the product. Battery = 90 days).

Our warranty is inclusive of shipping costs and is hassle free, the only warranty of this kind in the marketplace.Physical Dimensions:Nominal Voltage: 12VNominal Capacity: 2.3AhTerminal Type: PCWeight: 2 LbsLength: 7.17" (182 mm)Width: 0.91" (23 mm)Height: 2.40" (61 mm)The replacement battery for theLaerdal LSU Suction Unit consists of (1) High Quality 12V 2.3Ah battery. Laerdal does not provide Service Parts for this product. Disposable Canister and Patient Tubing

TEST Device Diagnostics program

Unable to locate a particular item that you are looking to purchase?

Battery TestTest Battery every 6-12 months.

hbbf`b``3 * Sw endstream endobj 290 0 obj <>/Metadata 15 0 R/Pages 14 0 R/StructTreeRoot 17 0 R/Type/Catalog/ViewerPreferences<>>> endobj 291 0 obj >/PageWidthList<0 595.276>>>>>>/Resources<>/Font<>/ProcSet[/PDF/Text/ImageC]/XObject<>>>/Rotate 0/StructParents 0/TrimBox[0.0 0.0 595.276 841.89]/Type/Page>> endobj 292 0 obj <> endobj 293 0 obj <>stream

=======

886100) can also be used with the previous model LCSU 3.

Check Battery level: While performing the Device Test the Battery level should not illuminate RED. Does the Laerdal Compact Suction Unit 4 (LCSU 4) Unit come with a battery or do you have to purchase them separately?

saving 300ml laerdal

Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the LCSU 4, including cables specified by the Laerdal Medical. Sign in or

An empty Battery must charge up to 5 hours to reach full capacity. suction laerdal unit machines respiratory equipment

Use of the AC/DC Adapter charger (Cat. 23.6 cm x 19 cm x 23.6 cm (9.3 x 7.5 x 9.3), 18.5 cm x 26.2 cm x 8.1 cm (7.3 x 10.3 x 3.2), Airflow at Vacuum Inlet (without canister attached), 30 LPM (free flow) typical (Maybe less when running from the internal battery).

Dry all surfaces using a clean cloth or paper towel.

Push the upper port connection into the Vacuum Inlet and check that the lower part of the Canister clicks in place.

lsu serres After suctioning, let LCSU 4 run for a moment to allow all suctioned material to flow from the Patient Tube into the Canister.

Learn more. Plug the larger connector into the vehicles 12V DC power receptacle. on Laerdal LCSU 4 Compact Suction Unit User Guide, Laerdal 3G Plus SimMan Head Skin User Guide. Please contact our friendly and reliable team on 01305 760750. All products sold by Life-Assist, Inc. are intended for use by trained medical personnel.

Welcome,visitor. NoteThe 800 ml Canister has an internal Filter in the Lid.

UPS Battery Center is in no way implying that any of its products are original equipment manufacturer replacement batteries.

Otherwise, degradation of the performance of this equipment could result. Keep all boxes and packaging materials and immediately contact customer service at (800) 824-6016 or email [emailprotected]. 0001217334 00000 n

Rx items are not available for resale.

======

allied suction lsp laerdal l190 1270 list

Thank you for considering Life-Assist for your supply and equipment needs.

Destinations outside of the 2 day shipping zone must be shipped 2nd Day Air and the air freight charges will apply.

Canisters and Patient Tubes Dispose of after use. Check that a suction catheter is attached to the patients suction tube or suction adapter.



Includes: Suction Unit, AC And DCCords,Disposable Canister and Patient Tubing, Battery, Vacuum Tubing and Directions forUse. Apply appropriate suction catheter (not supplied by Laerdal). No. The LCSU 4 operates, but little or no suction is available.

To restart, press the on/off switch.

You must have JavaScript enabled in your browser to utilize the functionality of this website. Internally powered/class I equipment type BF, according to IEC 60601-1, Protection class IP33 and standard power supply, Intermittent Operation: 30 minutes on, 30 minutes off. About EMP: Since 1972, Emergency Medical Products, Inc. has been a trusted distributor of EMS supplies, first aid products, and other pre-hospital and emergency medical supplies and equipment. Follow the procedure for adjusting the vacuum suction level, Battery or AC/DC adapter charger not connected or aged battery, Battery not fully charged or aged battery.

laerdal

Free Standard Shipping within the contiguous U.S. on orders over $100!

suction laerdal unit compact medical ferno units 800ml NoteAlways have an extra Canister available in case the first Canister is filled completely, or the suction unit tips onto its side and the Filter becomes saturated and stops the suction/flow. If the LCSU 4 does not receive external power, the Low Battery indicator will remain on and the unit performance will drop rapidly leading to a complete LCSU 4 shutdown. 0000044000 00000 n 0000009255 00000 n

5 year limited warranty (excluding the canisters, tubing systems and battery. Battery suction lsu laerdal unit eiremed ie airway management cart

Never connect any type of Patient Tubing directly to the LCSU 4 Vacuum Inlet Port Connection.

Overdue accounts: will be assessed a 1 1/2% monthly (18% year) charge.

5000 Tuttle Crossing Blvd.

laerdal

lsu laerdal suction battery unit airway management cpr rechargeable eiremed ie cart savers units

Extended warranty of up to 3 years is available for your convenience.

Home Laerdal Laerdal LCSU 4 Compact Suction Unit User Guide.

No.

Register.

CautionReplace the battery when it does not pass the battery test or after 2 years, whichever comes first. Electrically powered medical suction equipment for field and transport use, according to ISO10079-1. Not suitable for use in the presence of flammable liquids or gases. Carry BagsWipe Bags according to instructions provided above for Main Cabinet. 2022 UPS Battery Center Ltd. All Rights Reserved.

* The Battery can be left on the continuous charge, even if the Green LED is illuminated.

Do not use this unit until you have carefully read and fully understood these User Guides.

The Canister is disposable and cannot be cleaned.

Bemis Disposable Canister systems 880052/880062: Meets RTCA/DO-160G Section 21 Category M (for battery operation only; commercial aircraft, airborne equipment).Electromagnetic ConformityLCSU 4 is intended for use in the following environments: Professional Healthcare Facility environment, Home Healthcare environment and Emergency Medical Services environment.The essential performance of the LCSU 4 is identified as the connection of the patient hose to the exhaust outlet. Recharge the battery as soon as possible.

Check that the Filter has not been clogged (300 ml canister only). Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

Get FREE ground shipping on all orders $175+*.

0000003695 00000 n

Directions forUse. lsu serres 0000013293 00000 n UPS Battery Center Ltd. 555 Riverwalk Pkwy., Suite 100Tonawanda, NY14150 USA.

If necessary, contact Laerdal Medical or one of its authorized distributors. The filter automatically stops suction/flow when the canister is full, or the filter becomes saturated if the unit tips onto its side during use.

Clean the exterior and any reusable parts of the LCSU 4 assembly according to instructions (see Chapter 6). Disconnect the LCSU 4 from external power prior to cleaning.

No.

This product is in compliance with the essential requirements of Council Directive 93/42/EEC Medical Device Directive, as amended by Council Directive 2007/47/EC, class IIa, The degree of protection provided by the chassis according to IP33. This adds both a handle and a foot to the unit.



Click-in-place 300 ml canister, no vacuum tube needed, 800 ml canister option when extra volume is needed, Easy to convert between 300 and 800 ml canister version, Internal integrated filter systems for all canisters, Big vacuum regulator dial, with clicking sound, Children vacuum range area (marked in blue) on the control panel, Arrows pointing the vacuum directions High density carry bags, No-tools-necessary field changeable battery. PHILIPS 915005630101 Lily base unit User Manual, Regal G500 Series Temperature Control Unit User Manual, makita DVC150L Corded and Cordless Vacuum Cleaner Instruction Manual, hama 00200012 Universal USB-C Power Pack Instruction Manual, PETTADORE FS030 Hydrate Upgrade Warmer User Manual, RetroSound Grand Prix Radio Face Display Unit User Guide, PETTADORE PF005 Nutri Fresh Mini Feeder User Guide, Panasonic Corded Cordless Phone User Guide, GE Appliances GDF550PGR Front Control Dishwasher Installation Guide.

Sitemap 12

laerdal suction unit battery life